REXEED-LX Low Flux Dialyzers from Asahi
Asahi's unique membrane technology results
in less stimulation to blood components.

Asahi has achieved a new level of overall performance in dialyzer design by combining the new polysulfone membrane REXBRANE™ with a new jacket design allowing for optimum flow dynamics. Incorporated on the inner surface is Asahi’s unique hydrophilic gel layer technology. This minimizes blood membrane interaction and plays a crucial role in anti-coagulation requirements.
REXEED LX Low Flux Dry Dialyzer from Asahi
REXEED SX
REXEED-LX High Flux
Dry Dialyzer Series
Urea Clearance Comparison
vs Us Competitors
  • Surface areas from 1.5m2 to 2.5m2
  • REXBRANE membrane
  • New X-jacket design for improved flow dynamics
  • Exceptional toxin removal
  • Efficient heparin utilization
  • Required fluid volume for priming reduced to 500mL
  • Proprietary fiber inner gel layer minimizes platelet activation
  • ETO free and electron beam sterilized
  • Color coded headers
REXEED LX Urea Clearance Comparison
REXEED SX High Flux Dry Dialyzer
REXEED-LX Dialyzer Performance (in vitro)
 
REXEED-13LX
REXEED-15LX
Qd=500ml/min
Qd=800
ml/min
Qd=500ml/min
Qd=800
ml/min
Clearance
mL/min
Qb=200
mL/min
Qb=300
mL/min
Qb=400
mL/min
Qb=400
mL/min
Qb=200
mL/min
Qb=300
mL/min
Qb=400
mL/min
Qb=400
mL/min
Urea
193
259
301
334
195
266
312
346
Creatinine
186
239
274
304
190
248
288
319
Phosphate
154
185
201
220
161
195
214
236
Vitamin B12
93
102
106
113
100
110
116
125
KOA (Urea)
1009
1149
UFR
(mL/hr/mmHG)
9
10
REXEED-18LX
REXEED-21LX
Qd=500ml/min
Qd=800
ml/min
Qd=500ml/min
Qd=800
ml/min
Clearance
mL/min
Qb=200
mL/min
Qb=300
mL/min
Qb=400
mL/min
Qb=400
mL/min
Qb=200
mL/min
Qb=300
mL/min
Qb=400
mL/min
Qb=400
mL/min
Urea
197
271
322
355
198
277
332
366
Creatinine
193
255
299
332
195
264
313
347
Phosphate
167
204
226
251
173
215
241
269
Vitamin B12
107
118
125
136
115
129
137
151
KOA (Urea)
1279
1483
UFR
(mL/hr/mmHG)
12
14
• KUF: with bovine blood, TP = 60±5 g?L, Hct. = 32±2%, Qb = 300 mL/min
• Clearance: Qf= 0 mL/min • KoA: Qb = 400 mL/min, Qd = 800 mL/min, Qf = 0 mL/min
REXEED SX High Flux Dry Dialyzers
REXEED-LX Dialyzer Specifications
 
REXEED-13LX
REXEED-15LX
Inside Diameter of Hollow Fiber (um)
185
185
Wall Thickness of Hollow Fiber (um)
35
35
Effective Surface Area
1.3
1.5
Priming Volume (mL)
88
100
Max. TMP
66 kPa (500 mmHg)
66 kPa (500 mmHg)
Dimensions (mm [L] x mm [D]
334(L) x 34(D)
334(L) x 38(D)
Sterilization
Electron Beam
Electron Beam
REXEED-18LX
REXEED-21LX
Inside Diameter of Hollow Fiber (um)
185
185
Wall Thickness of Hollow Fiber (um)
35
35
Effective Surface Area
1.8
2.1
Priming Volume (mL)
119
137
Max. TMP
66 kPa (500 mmHg)
66 kPa (500 mmHg)
Dimensions (mm [L] x mm [D]
334(L) x 41(D)
334(L) x 43(D)
Sterilization
Electron Beam
Electron Beam