- Highest performance dialyzer in the US
- Improved anticoagulation / less heparin
- Available in four sizes:
2.5m2 / 2.1m2 / 1.8m2 / 1.5m2 - 2.5 m2 - highest performance dialyzer offered today
- 1.5 m2 is ideal for Acute Patients
Single and Multiple use - Gamma sterilized (No ETO residuals )
- 2.5m2 - Alternative to “Tandem Dialysis”
- High middle molecule removal
- Next generation polysulfone membrane REXBRANE
- Exceptional urea, creatinine and phosphate clearances
Improved Anticoagulation
Asahi’s unique membrane technology contributes to improved anticoagulation. Asahi’s hydrophilic gel layer helps to reduce the interaction between blood components and the membrane surface as illustrated below.

This reduces the potential for platelet activation and protein adhesion to the membrane. REXEED dialyzers frequently require less heparin than other dialyzers (graph below).

The improved flow dynamics of REXEED are provided by Asahi’s new high performance jacket design that provides a uniform dialysate flow.
The waved fiber design in REXEED provides smooth blood flow and improved dailysate penetration into the middle of the bundle for ideal dialysate / fiber contact and ideal small molecule clearance.

The ideal flow pattern is shown as a symmetrical sharp peak (above) that suggests quick dialysate turnover leading to exceptional small molecule clearance.
Balanced and Comprehensive
Small Molecule Clearance
REXEED has been developed to provide well balanced and comprehensive small and middle molecule clearance while minimizing albumin loss. This is demonstrated by the triangular graph (below).

Dialyzer |
Size M2 |
Flux |
Sterilization |
Use |
Membrane |
KOA |
Package |
| REXEED 15 | 1.5 |
Hi-Flux |
Gamma |
Single / Re-Use |
Polysulfone (Rexbrane) |
1232 |
12 / Case |
| REXEED 18 | 1.8 |
Hi-Flux |
Gamma |
Single / Re-Use |
Polysulfone (Rexbrane) |
1483 |
12 / Case |
| REXEED 21 | 2.1 |
Hi-Flux |
Gamma |
Single / Re-Use |
Polysulfone (Rexbrane) |
1683 |
12 / Case |
| REXEED 25 | 2.5 |
Hi-Flux |
Gamma |
Single / Re-Use |
Polysulfone (Rexbrane) |
1881 |
12 / Case |
REXEED Dialyzer Performance (in vitro)
REXEED-15 |
REXEED-18 |
|||||||
Qd=500ml/min |
Qd=800 ml/min |
Qd=500ml/min |
Qd=800 ml/min |
|||||
Clearance mL/min |
Qb=200 mL/min |
Qb=300 mL/min |
Qb=400 mL/min |
Qb=400 mL/min |
Qb=200 mL/min |
Qb=300 mL/min |
Qb=400 mL/min |
Qb=400 mL/min |
Urea |
196 |
272 |
317 |
352 |
198 |
280 |
330 |
366 |
Creatinine |
191 |
255 |
296 |
326 |
194 |
265 |
309 |
341 |
Phosphate |
185 |
238 |
272 |
301 |
190 |
250 |
289 |
320 |
Vitamin B12 |
142 |
168 |
179 |
199 |
152 |
183 |
197 |
219 |
KOA (Urea) |
1232 |
1483 |
||||||
UFR (mL/hr/mmHG) |
63 |
71 |
||||||
REXEED-21 |
REXEED-25 |
|||||||
Qd=500ml/min |
Qd=800 ml/min |
Qd=500ml/min |
Qd=800 ml/min |
|||||
Clearance mL/min |
Qb=200 mL/min |
Qb=300 mL/min |
Qb=400 mL/min |
Qb=400 mL/min |
Qb=200 mL/min |
Qb=300 mL/min |
Qb=400 mL/min |
Qb=400 mL/min |
Urea |
199 |
284 |
340 |
374 |
199 |
287 |
350 |
380 |
Creatinine |
195 |
272 |
317 |
352 |
196 |
280 |
330 |
364 |
Phosphate |
192 |
257 |
299 |
334 |
194 |
260 |
303 |
346 |
Vitamin B12 |
160 |
194 |
212 |
236 |
163 |
199 |
225 |
251 |
KOA (Urea) |
1683 |
1881 |
||||||
UFR (mL/hr/mmHG) |
74 |
80 |
||||||